eCerto is an online tool written in R/Shiny to facilitate the statistical evaluation of data collected in connection with the production of certified reference materials (CRMs) at Bundesanstalt für Materialforschung und -prüfung (BAM).
The standard workflow consists of a certification trial in combination with homogeneity and stability assays. Data from all of these assays need to be collected, combined and analyzed to report certified values of measured properties or entities of a reference material.
The tool provides some example data to test the functionality on the
Start page. Here, previous analyses can be read from a
backup file and will contain all input data and previously set
parameters.
A new analysis can be started by importing data from Excel but should
be stored after statistical analyes together with your user name and a
trial ID as an RData-file data (Backup).
The statistics for reference material certification with eCerto is implemented according to ISO GUIDE 35:2017.
To make the calculations transparent for the user and facilitate
using this tool, the relevant section of the documentation (from page
Help) can be obtained in a modal/pop-up window by clicking
on the respective links.
Links should be rendered in blue color on your screen. Often, table or figure captions are used for this purpose, so watch out for help-links close to the area you are working on.
You’ll find a working example on page Start (–>
Load Test Data). To upload your own data, tables have
to be prepared in Excel using specific cell formats, column names and
column orders. To learn about these formats you can click on the word
example right over the select box.
Magic: the help section opened by this link is dependent on the value
selected in the box.
Note! To close a help window you need to click anywhere outside of it with your mouse.
To process a new analysis, please collect all data which should be returned in pre-defined Excel-Files by your certification trial partners and stored within one folder. Pre-defined means that the analytical results are at the same position within each file (table name, row and column range) and that exactly one file per laboratory exists.
This approach resembles a frequent workflow and facilitates to keep the data originally send by the partner laboratories as is, without the need to combine them prior to upload, while being able to directly import them into eCerto and start with the evaluation.
The smallest possible test data file would look like this:
A | B | C | D | E | |
|---|---|---|---|---|---|
1 | X | mg | 1.03 | 0.98 | 1.07 |
It contains data for a single analyte X, measured in unit mg with three replicate values. You would need at least one more file, preferably with different values for X, to be able to start an upload. Replicate measurements and a sufficient number of partner labs are required to perform the statistical tests implemented in eCerto.
In reality, the analyte data will be just a part of the table returned by the partner laboratories, which is why eCerto allows you to select a specific cell range in a preview window as described below.
Note! Please select the range without a header as shown in the figure below. eCerto assumes the first and second column of the specified range to contain analyte names and units respectively and replicate measurements of this analyte in all remaining columns.
File names will be stored for reference but imported labs will be consecutively numbered. In the example above you would import data from sheet 1 of each Excel file located in Range A7:H9, containing 6 replicate measurements of 3 different analytes (column A) measured in units as specified in column B.
eCerto can deal with missing values (empty replicates for specific analytes) and also with some partner labs not providing any data for particular analytes at all. However, ensure that the cell range is identical in all imported files. Preferably, you provide a template file for partner laboratories where only cells intended for measurement values can be edited while other cells are write protected.
Note! Currently, eCerto needs to load all Excel result files in one step, i.e. you can not add additional files later on but would have to start all over again. However, this is reasonable as statistics will change upon addition of new values which in turn might require adjustments in rounding precision or filtered labs.
For analytes under inspection (i.e. which are selected in Tab.C3), several analyte specific parameters can be set and will be stored also in the backup file.
pooling means that calculations in the material table
(mean, sd and uncertainty columns) are not
based on the lab means, but rather on all measured values. This
is justified when the between lab variance is smaller than the within
lab variance (check if the ANOVA P-value is insignificant in
Tab.C2, if so pooling might be allowed).
Selecting this option will also affect n in
Tab.C3 being either the number of included labs or the
number of finite data points from these labs.
Individual Samples can be filtered by ID (select
show IDs in Fig.C1 to identify outlying
IDs). These samples will not be used in any calculations. They
are removed from downstream processing right after import. However,
information of this filtering step is preserved and included in
reports.
Labs can be excluded by Lab-ID. Please note, that this is done after statistical testing for mean and variance outliers (in Tab.C1 and Tab.C2). Filtered labs are depicted in Fig.C1 (using grey color), but excluded from calculating the certified value of the analyte in Tab.C3.
Note! Internally, all calculations are
performed on non-rounded values (as imported). Only the visual
output to the user is rounded to improve readability. Because analytes
within an RM might be measured at very different scales it is possible
to define analyte specific precision values for rounding. The
Precision (Tables) value is used for most values displayed
in tables.
The only exception is Tab.C3. Here,
Precision (µ_c) is used to round \(\mu_c\) and \(U_{abs}\) to allow to comply with DIN/ISO
regulations on rounding and columns containing relative uncertainties
are rounded to fixed 4 digit precision.
The user can decide the rounding precision for \(\mu_c\) and \(U_{abs}\) and even specify negative numbers
for Precision (µ_c) to indicate a desired rounding digit
left of the decimal separator (i.e. \(-1\) to round an uncertainty of 13.1 up to
20). If the uncertainty is even larger, the user should consider to
upload data using a different (more appropriate) unit and, for instance,
switch from mg/L to g/L.
eCerto suggests the rounding precision for \(\mu_c\) and \(U_{abs}\) according to DIN 1333. The
appropriate value is displayed right over the input box of
Precision (µ_c). It’s background is colored green if it is in accordance
with the user selected value and red otherwise.
The significant digit is determined based on the first non-zero digit
in \(U_{abs}\). The position will be
shown above the analyte parameter Precision (µ_c) upon
selection of an analyte in Tab.C3. Once found, the
respective digit will be rounded up for \(\mu_c\) if the consecutive digit is \(\ge 5\) and down otherwise. For \(U_{abs}\) the rounding procedure is a bit
more complicated. If the respective digit is 1 or 2, than the
consecutive digit will be rounded up. If the respective digit is \(\ge 3\), than it will be rounded up
itself.
For an analyte selected in Tab.C3 various
statistical tests regarding lab means and variance will be performed
according to ISO 17025 and outlying values will be indicated if observed
at the .05 and .01 level respectively. The
displayed values n.s. and . indicate either
that the test probability was >0.05 or that this lab was not tested
because it did not contain an extreme value.
Note! eCerto performs outlier tests at the lower and upper end of the value distribution independently (i.e. two one sided tests). This might lead to confusion as P-values for both independent tests are displayed within the same column of Tab.C1. However, it allows to keep the output compact. Please always use results of Tab.C1 in parallel with Fig.C1 to decide on the removal of Labs.
Lab | mean | sd | n | Scheffe.05 | Scheffe.01 | Dixon | Grubbs1 | Grubbs2 | Cochran |
|---|---|---|---|---|---|---|---|---|---|
L07 | 0.0455 | 0.0008 | 6 | f | d | n.s. | n.s. | n.s. | |
L01 | 0.0455 | 0.0013 | 6 | f | d | . | . | n.s. | [2] .05 |
L06 | 0.0483 | 0.0001 | 6 | e | c | . | . | . | |
L08 | 0.0486 | 0.0002 | 6 | de | c | . | . | . | |
L10 | 0.0493 | 0.0002 | 6 | cde | bc | . | . | . | |
L16 | 0.0500 | 0.0009 | 6 | bcde | bc | . | . | . | . |
L15 | 0.0505 | 0.0004 | 6 | abcd | abc | . | . | . | |
L03 | 0.0513 | 0.0005 | 6 | abc | ab | . | . | . | |
L02 | 0.0515 | 0.0008 | 6 | ab | ab | . | . | n.s. | |
L13 | 0.0524 | 0.0016 | 6 | a | a | n.s. | n.s. | n.s. | [1] .01 |
Except for Cochran, which tests for outliers with
respect to variance, all other columns indicate potential outliers
regarding lab means.
To compute the statistical tests eCerto uses functions from different packages available for R. Details regarding the conducted statistical test (implementation, parameters) can be found using the following links:
agricolae
package.excl indicates that the sd of a lab
was too low and the lab was removed from the testing procedure.Note! Most tests require at least 3 data
points (Labs) and finite differences in Lab means and Lab variances. If
these conditions are not fulfilled Error might be reported
instead of a P-value.
Instead of the qualitative significance levels reached in the test,
the options panel to the right of Tab.C1 offers the
possibility to display the calculated P-values directly for
most of the tests. Further, the calculated test statistic
values can be displayed. The user can also select to show the
critical values at \(\alpha=0.05\) and \(\alpha=0.01\). Depending on the test these
are calculated based on the underlying distributions or obtained from
tabulated values.
If any lab is excluded after using the filter section of the analyte
panel on top of the page, all tests in Tab.C1 can be
conducted without filtered labs selecting the option
Exclude filtered Labs. This feature allows to confirm
whether or not further outliers are present in the data set. Please use
the possibility to remove outliers sequentially with caution,
i.e. refrain from over exclusion of initially masked
outliers.
The distribution of lab means is evaluated using a variety of
recommended tests. Normality of the distribution is tested using the
KS-Test. Besides mean and sd the robust
alternatives median and MADare provided.
Columns of the form testnamep provide P-values of
the respective tests. Skewness and Kurtosis are computed additionally
and grouped with their respective tests (Agostino and Anscombe).
Mean | Median | SD | MAD | Bartlettp | ANOVAp | KSp | Skewness | Agostinop | Kurtosis | Anscombep |
|---|---|---|---|---|---|---|---|---|---|---|
1.257 | 1.256 | 0.013 | 0.016 | 8.60E-05 | 0.6091 | 0.9640 | 0.03 | 1.38 | 0.2049 |
To compute the statistical tests eCerto uses functions from different packages available for R. Details regarding the conducted statistical test can be found using the following links:
pooling option (Tab.C3) for this analyte if the
ANOVA P-value be not significant.Skewness and
Kurtosis are computed using a two-sided alternative.Additionally to checking the KS test P-value, deviation
of the data from a normal distribution can also be visually investigated
by opening a QQ-plot using the respective link.
Lab means and their measurement distribution is depicted in a standard graphic layout which can be exported as vector graphic (PDF) for further editing. Labs which have been identified as outliers in Tab.C1 can be excluded from the overall mean calculation in the analyte parameter section at the top of the page. This decision has to be made by the user, eCerto will not remove any outlier automatically. However, eCerto keeps track of the removal and indicates the omitted lab values in the plot as grey data points.
Besides width and height adjustment, the
plot can be modified to include individual measurement using their ID
(Show sample IDs). This can be useful to identify potential
individual outlier samples. Further, x-axis annotation can be altered to
show anonymous Lx values or the imported file names as
labels.
A report of the current analysis (single analyte) or for the material (Tab.C3) can be generated and exported in HTML or DOCX format.
Additionally, Tab.C3 can be exported to Digital Reference Material Document (DRMD) format, which is currently under development.
Note! The current report layouts are for demonstration purpose only. Very likely, we will implement a set of recommended report layouts in the future upon user suggestions.
Tests used for outlier detection often rely on tabulated critical values. Decisions to reject or not reject a potential outlier can be dependent on the source of the critical values.
Where ever possible, we tried to omit using fixed tables and rather implemented critical value calculation ab initio. However, to be transparent, we detail the mathematical approach for each test in the following.
Note! Several test functions were
implemented based on the functions in the R package
outliers by Lukasz Komsta. Modifications were made to allow
testing up to n=100 laboratories (was restricted to n=30 in package
outliers).
eCerto:::qcochran
## function(p, n, k) {
## f <- stats::qf(p / k, (n - 1) * (k - 1), n - 1)
## c <- 1 / (1 + (k - 1) * f)
## return(c)
## }
## <bytecode: 0x000001a8189418c0>
## <environment: namespace:eCerto>
stats::qf() is the quantile
function of the f-distribution as implemented in the R
stats package. Likewise, stats::pf() is used
to compute the Cochran P-value via function
eCerto:::pcochran
## function(q, n, k) {
## f <- (1 / q - 1) / (k - 1)
## p <- 1 - stats::pf(f, (n - 1) * (k - 1), n - 1) * k
## p[p < 0] <- 0
## p[p > 1] <- 1
## return(p)
## }
## <bytecode: 0x000001a820c22e08>
## <environment: namespace:eCerto>
ps <- c(0.01, 0.05)
ns <- c(3:9, seq(10,20,5))
ks <- c(2:14, seq(15,30,5))
out <- lapply(ps, function(p) {
sapply(ns, function(n) {
sapply(ks, function(k) {
eCerto:::qcochran(p=p, n=n, k=k)
})
})
})
names(out) <- paste0("alpha=", ps)
lapply(out, function(x) {
colnames(x) <- paste0("n=", ns)
rownames(x) <- paste0("k=", ks)
round(x, 4)
})
## $`alpha=0.01`
## n=3 n=4 n=5 n=6 n=7 n=8 n=9 n=10 n=15 n=20
## k=2 0.9950 0.9794 0.9586 0.9373 0.9172 0.8988 0.8823 0.8674 0.8113 0.7744
## k=3 0.9423 0.8832 0.8335 0.7933 0.7606 0.7335 0.7107 0.6912 0.6241 0.5838
## k=4 0.8643 0.7814 0.7212 0.6761 0.6410 0.6129 0.5897 0.5702 0.5054 0.4678
## k=5 0.7885 0.6957 0.6329 0.5875 0.5531 0.5259 0.5038 0.4853 0.4251 0.3907
## k=6 0.7218 0.6258 0.5635 0.5195 0.4866 0.4609 0.4401 0.4229 0.3672 0.3360
## k=7 0.6644 0.5685 0.5080 0.4659 0.4347 0.4105 0.3911 0.3751 0.3237 0.2950
## k=8 0.6152 0.5210 0.4627 0.4227 0.3932 0.3705 0.3523 0.3373 0.2896 0.2632
## k=9 0.5727 0.4810 0.4251 0.3870 0.3592 0.3378 0.3207 0.3067 0.2622 0.2377
## k=10 0.5358 0.4469 0.3934 0.3572 0.3308 0.3106 0.2945 0.2814 0.2397 0.2169
## k=11 0.5036 0.4175 0.3663 0.3318 0.3068 0.2876 0.2725 0.2601 0.2209 0.1995
## k=12 0.4751 0.3919 0.3428 0.3099 0.2861 0.2680 0.2536 0.2419 0.2049 0.1848
## k=13 0.4498 0.3695 0.3223 0.2909 0.2682 0.2509 0.2373 0.2261 0.1911 0.1721
## k=14 0.4272 0.3495 0.3042 0.2741 0.2525 0.2360 0.2230 0.2124 0.1792 0.1612
## k=15 0.4069 0.3318 0.2882 0.2593 0.2386 0.2228 0.2104 0.2003 0.1687 0.1516
## k=20 0.3297 0.2654 0.2288 0.2048 0.1877 0.1748 0.1646 0.1564 0.1308 0.1170
## k=25 0.2782 0.2220 0.1904 0.1699 0.1553 0.1443 0.1357 0.1287 0.1071 0.0956
## k=30 0.2412 0.1914 0.1635 0.1455 0.1327 0.1231 0.1156 0.1096 0.0909 0.0809
##
## $`alpha=0.05`
## n=3 n=4 n=5 n=6 n=7 n=8 n=9 n=10 n=15 n=20
## k=2 0.9750 0.9392 0.9057 0.8772 0.8534 0.8332 0.8159 0.8010 0.7487 0.7164
## k=3 0.8709 0.7977 0.7457 0.7070 0.6770 0.6531 0.6333 0.6167 0.5613 0.5289
## k=4 0.7679 0.6839 0.6287 0.5894 0.5598 0.5365 0.5175 0.5018 0.4500 0.4205
## k=5 0.6838 0.5981 0.5440 0.5063 0.4783 0.4564 0.4387 0.4241 0.3767 0.3500
## k=6 0.6161 0.5321 0.4803 0.4447 0.4184 0.3980 0.3817 0.3682 0.3247 0.3004
## k=7 0.5612 0.4800 0.4307 0.3972 0.3726 0.3536 0.3384 0.3259 0.2858 0.2635
## k=8 0.5157 0.4377 0.3910 0.3594 0.3362 0.3185 0.3043 0.2927 0.2556 0.2350
## k=9 0.4775 0.4027 0.3584 0.3285 0.3067 0.2901 0.2768 0.2659 0.2313 0.2122
## k=10 0.4450 0.3733 0.3311 0.3028 0.2823 0.2666 0.2541 0.2439 0.2115 0.1936
## k=11 0.4169 0.3482 0.3080 0.2811 0.2616 0.2468 0.2350 0.2254 0.1949 0.1782
## k=12 0.3924 0.3264 0.2880 0.2624 0.2440 0.2299 0.2187 0.2096 0.1808 0.1650
## k=13 0.3709 0.3074 0.2707 0.2463 0.2286 0.2152 0.2046 0.1960 0.1687 0.1538
## k=14 0.3517 0.2907 0.2554 0.2321 0.2153 0.2025 0.1924 0.1841 0.1582 0.1440
## k=15 0.3346 0.2758 0.2419 0.2195 0.2034 0.1912 0.1815 0.1737 0.1489 0.1355
## k=20 0.2705 0.2205 0.1921 0.1735 0.1602 0.1502 0.1422 0.1358 0.1157 0.1048
## k=25 0.2281 0.1846 0.1601 0.1441 0.1328 0.1242 0.1174 0.1120 0.0949 0.0857
## k=30 0.1979 0.1593 0.1377 0.1236 0.1137 0.1061 0.1003 0.0955 0.0806 0.0727
The test is originally based on:
“Snedecor, G.W., Cochran, W.G. (1980). Statistical Methods (seventh
edition). Iowa State University Press, Ames, Iowa”.
eCerto:::dixon.test
## function(x, opposite = FALSE, two.sided = FALSE) {
## x <- sort(x[stats::complete.cases(x)])
## n <- length(x)
## if (n <= 7) {
## type <- "10"
## } else if (n > 7 & n <= 10) {
## type <- "11"
## } else if (n > 10 & n <= 13) {
## type <- "21"
## } else {
## type <- "22"
## }
## if (xor(((x[n] - mean(x)) < (mean(x) - x[1])), opposite)) {
## alt <- paste("lowest value", x[1], "is an outlier")
## q <- switch(type,
## "10" = (x[2] - x[1]) / (x[n] - x[1]),
## "11" = (x[2] - x[1]) / (x[n - 1] - x[1]),
## "21" = (x[3] - x[1]) / (x[n - 1] - x[1]),
## (x[3] - x[1]) / (x[n - 2] - x[1])
## )
## } else {
## alt <- paste("highest value", x[n], "is an outlier")
## q <- switch(type,
## "10" = (x[n] - x[n - 1]) / (x[n] - x[1]),
## "11" = (x[n] - x[n - 1]) / (x[n] - x[2]),
## "21" = (x[n] - x[n - 2]) / (x[n] - x[2]),
## (x[n] - x[n - 2]) / (x[n] - x[3])
## )
## }
## pval <- pdixon(q, n)
## if (two.sided) {
## pval <- 2 * pval
## if (pval > 1) pval <- 2 - pval
## }
## out <- list(
## "statistic" = c(Q = q),
## "alternative" = alt,
## "p.value" = pval,
## "method" = "Dixon test for outliers",
## "data.name" = "eCerto internal"
## )
## class(out) <- "htest"
## return(out)
## }
## <bytecode: 0x000001a82057b190>
## <environment: namespace:eCerto>
In eCerto the one-sided version of the
Dixon test is applied consecutively at the lower and upper end. Critical
values are stored in tabulated form internally
(eCerto::cvals_Dixon) and have been combined in a single
table from
this
source.
## 0.001 0.002 0.005 0.01 0.02 0.05 0.1 0.2
## 3 0.999 0.998 0.994 0.988 0.976 0.941 0.886 0.782
## 4 0.964 0.949 0.921 0.889 0.847 0.766 0.679 0.561
## 5 0.895 0.869 0.824 0.782 0.729 0.643 0.559 0.452
## 6 0.822 0.792 0.744 0.698 0.646 0.563 0.484 0.387
## 7 0.763 0.731 0.681 0.636 0.587 0.507 0.433 0.344
## 8 0.799 0.769 0.724 0.682 0.633 0.554 0.480 0.386
## 9 0.750 0.720 0.675 0.634 0.586 0.512 0.441 0.352
## 10 0.713 0.683 0.637 0.597 0.551 0.477 0.409 0.325
## 11 0.770 0.746 0.708 0.674 0.636 0.575 0.518 0.445
## 12 0.739 0.714 0.676 0.643 0.605 0.546 0.489 0.420
## 13 0.713 0.687 0.649 0.617 0.580 0.522 0.467 0.399
## 14 0.732 0.708 0.672 0.640 0.603 0.546 0.491 0.422
## 15 0.708 0.685 0.648 0.617 0.582 0.524 0.470 0.403
## 16 0.691 0.667 0.630 0.598 0.562 0.505 0.453 0.386
## 17 0.671 0.647 0.611 0.580 0.545 0.489 0.437 0.373
## 18 0.652 0.628 0.594 0.564 0.529 0.475 0.424 0.361
## 19 0.640 0.617 0.581 0.551 0.517 0.462 0.412 0.349
## 20 0.627 0.604 0.568 0.538 0.503 0.450 0.401 0.339
## 25 0.574 0.550 0.517 0.489 0.457 0.406 0.359 0.302
## 30 0.539 0.517 0.484 0.456 0.425 0.376 0.332 0.278
## 35 0.511 0.490 0.459 0.431 0.400 0.354 0.311 0.260
## 40 0.490 0.469 0.438 0.412 0.382 0.337 0.295 0.246
## 45 0.475 0.454 0.423 0.397 0.368 0.323 0.283 0.234
## 50 0.460 0.439 0.410 0.384 0.355 0.312 0.272 0.226
## 60 0.437 0.417 0.388 0.363 0.336 0.294 0.256 0.211
## 70 0.422 0.403 0.374 0.349 0.321 0.280 0.244 0.201
## 80 0.408 0.389 0.360 0.337 0.310 0.270 0.234 0.192
## 90 0.397 0.377 0.350 0.326 0.300 0.261 0.226 0.185
## 100 0.387 0.368 0.341 0.317 0.292 0.253 0.219 0.179
eCerto:::qtable
## function(p, probs, quants) {
## quants <- quants[order(probs)]
## probs <- sort(probs)
## res <- vector()
## for (n in 1:length(p)) {
## pp <- p[n]
## if (pp <= probs[1]) {
## q0 <- quants[c(1, 2)]
## p0 <- probs[c(1, 2)]
## fit <- stats::lm(q0 ~ p0)
## } else if (pp >= probs[length(probs)]) {
## q0 <- quants[c(length(quants) - 1, length(quants))]
## p0 <- probs[c(length(probs) - 1, length(probs))]
## fit <- stats::lm(q0 ~ p0)
## } else {
## x0 <- which(abs(pp - probs) == min(abs(pp - probs)))
## x1 <- which(abs(pp - probs) == sort(abs(pp - probs))[2])
## x <- min(c(x0, x1))
## if (x == 1) {
## x <- 2
## }
## if (x > length(probs) - 2) {
## x <- length(probs) - 2
## }
## i <- c(x - 1, x, x + 1, x + 2)
## q0 <- quants[i]
## p0 <- probs[i]
## fit <- stats::lm(q0 ~ poly(p0, 3))
## }
## res <- c(res, stats::predict(fit, newdata = list(p0 = pp)))
## }
## return(res)
## }
## <bytecode: 0x000001a8205871c0>
## <environment: namespace:eCerto>
The test is originally based on:
“Dixon, W.J. (1950). Analysis of extreme values. Ann. Math. Stat. 21, 4,
488-506”
“Dean, R.B.; Dixon, W.J. (1951). Simplified statistics for small numbers
of observations. Anal.Chem. 23, 636-638”
“Dixon, W.J. (1953). Processing data for outliers. J. Biometrics. 9,
74-89”
eCerto:::grubbs.test
## function(x, type = 10, tail = c("lower", "upper")) {
## tail <- match.arg(tail)
## if (!any(type == c(10, 20))) {
## e_msg("is only implemented for type = 10 or 20. Using type = 20 (double Grubbs).")
## }
## x <- sort(x[stats::complete.cases(x)])
## n <- length(x)
## if (type == 10) {
## # single Grubbs
## if (tail == "lower") {
## alt <- paste("lowest value", x[1], "is an outlier")
## o <- x[1]
## d <- x[2:n]
## } else {
## alt <- paste("highest value", x[n], "is an outlier")
## o <- x[n]
## d <- x[1:(n - 1)]
## }
## g <- abs(o - mean(x)) / stats::sd(x)
## u <- stats::var(d) / stats::var(x) * (n - 2) / (n - 1)
## pval <- 1 - pgrubbs(g, n, type = 10)
## method <- "Grubbs test for one outlier"
## } else {
## # double Grubbs
## if (tail == "lower") {
## alt <- paste("lowest values", x[1], "and", x[2], "are outliers")
## u <- stats::var(x[3:n]) / stats::var(x) * (n - 3) / (n - 1)
## } else {
## alt <- paste("highest values", x[n - 1], "and", x[n], "are outliers")
## u <- stats::var(x[1:(n - 2)]) / stats::var(x) * (n - 3) / (n - 1)
## }
## g <- NULL
## pval <- pgrubbs(u, n, type = 20)
## method <- "Grubbs test for two outliers"
## }
## out <- list(
## "statistic" = c(G = g, U = u),
## "alternative" = alt,
## "p.value" = pval,
## "method" = method,
## "data.name" = "eCerto internal"
## )
## class(out) <- "htest"
## return(out)
## }
## <bytecode: 0x000001a8208914d0>
## <environment: namespace:eCerto>
eCerto:::qgrubbs
## function(p, n, type = 10, rev = FALSE) {
## if (type == 10) {
## if (!rev) {
## t2 <- stats::qt((1 - p) / n, n - 2)^2
## return(((n - 1) / sqrt(n)) * sqrt(t2 / (n - 2 + t2)))
## } else {
## s <- (p^2 * n * (2 - n)) / (p^2 * n - (n - 1)^2)
## t <- sqrt(s)
## if (is.nan(t)) {
## res <- 0
## } else {
## res <- n * (1 - stats::pt(t, n - 2))
## res[res > 1] <- 1
## }
## return(1 - res)
## }
## } else {
## if (n > 30) warning("[qgrubbs] critical value is estimated for n>30")
## gtwo <- eCerto::cvals_Grubbs2
## pp <- as.numeric(colnames(gtwo))
## if (!rev) res <- qtable(p, pp, gtwo[n - 3, ]) else res <- qtable(p, gtwo[n - 3, ], pp)
## res[res < 0] <- 0
## res[res > 1] <- 1
## return(unname(res))
## }
## }
## <bytecode: 0x000001a8209679a8>
## <environment: namespace:eCerto>
ps <- c(0.01, 0.025, 0.05, 0.1)
ns <- c(3:10, seq(20,100,40))
out <- sapply(ps, function(p) {
sapply(ns, function(n) {
eCerto:::qgrubbs(p=p, n=n)
})
})
colnames(out) <- paste0("a=", ps)
rownames(out) <- paste0("n=", ns)
round(out, 4)
## a=0.01 a=0.025 a=0.05 a=0.1
## n=3 0.5878 0.6033 0.6289 0.6787
## n=4 0.7575 0.7688 0.7875 0.8250
## n=5 0.8863 0.8961 0.9123 0.9452
## n=6 0.9892 0.9981 1.0131 1.0435
## n=7 1.0744 1.0828 1.0969 1.1258
## n=8 1.1469 1.1549 1.1685 1.1962
## n=9 1.2098 1.2176 1.2307 1.2576
## n=10 1.2652 1.2728 1.2856 1.3118
## n=20 1.6118 1.6184 1.6297 1.6529
## n=60 2.0999 2.1057 2.1155 2.1358
## n=100 2.3040 2.3095 2.3188 2.3381
eCerto::cvals_Grubbs2) and P-values are
derived by comparison.
## 0.01 0.025 0.05 0.1
## 4 0.0000 0.0002 0.0008 0.0031
## 5 0.0035 0.0090 0.0183 0.0376
## 6 0.0186 0.0349 0.0565 0.0921
## 7 0.0440 0.0708 0.1020 0.1479
## 8 0.0750 0.1101 0.1478 0.1994
## 9 0.1082 0.1492 0.1909 0.2454
## 10 0.1415 0.1865 0.2305 0.2863
## 20 0.3909 0.4391 0.4804 0.5269
## 60 0.7089 0.7346 0.7553 0.7775
## 100 0.8018 0.8190 0.8326 0.8470
Note! Critical values for double
Grubbs are obtained from the outliers package for 4≤n≤30
and are estimated for 31≤n≤100 based on the approximation described in
this
paper.
The test is originally based on:
“Grubbs, F.E. (1950). Sample Criteria for testing outlying observations.
Ann. Math. Stat. 21, 1, 27-58”.
agricolae package. It
is calculated on the result of stats::lm().
eCerto:::scheffe.test
## function(y, trt, alpha = 0.05) {
## name.y <- paste(deparse(substitute(y)))
## name.t <- paste(deparse(substitute(trt)))
## A <- y$model
## DFerror <- stats::df.residual(y)
## MSerror <- stats::deviance(y) / DFerror
## y <- A[, 1]
## ipch <- pmatch(trt, names(A))
## nipch <- length(ipch)
## for (i in 1:nipch) {
## if (is.na(ipch[i])) {
## return(trt)
## }
## }
## name.t <- names(A)[ipch][1]
## trt <- A[, ipch]
## if (nipch > 1) {
## trt <- A[, ipch[1]]
## for (i in 2:nipch) {
## name.t <- paste(name.t, names(A)[ipch][i], sep = ":")
## trt <- paste(trt, A[, ipch[i]], sep = ":")
## }
## }
## name.y <- names(A)[1]
## df <- subset(data.frame("value" = y, "Lab" = trt), is.na(y) == FALSE)
## # JL
## means <- ldply_base(split(df$value, df$Lab), function(x) {
## data.frame(
## "mean" = mean(x, na.rm = T),
## "sd" = stats::sd(x, na.rm = T),
## "n" = sum(is.finite(x)),
## stringsAsFactors = FALSE
## )
## }, .id = "Lab")
## ntr <- nrow(means)
## Fprob <- stats::qf(1 - alpha, ntr - 1, DFerror)
## Tprob <- sqrt(Fprob * (ntr - 1))
## nr <- unique(means[, 4])
## scheffe <- Tprob * sqrt(2 * MSerror / nr)
## statistics <- data.frame(
## "MSerror" = MSerror,
## "Df" = DFerror,
## "F" = Fprob,
## "Mean" = mean(df[, 1]),
## "CV" = sqrt(MSerror) * 100 / mean(df[, 1])
## )
## if (length(nr) == 1) {
## statistics <- data.frame(statistics, "Scheffe" = Tprob, "CriticalDifference" = scheffe)
## }
## comb <- utils::combn(ntr, 2)
## nn <- ncol(comb)
## dif <- rep(0, nn)
## LCL <- dif
## UCL <- dif
## pval <- rep(0, nn)
## for (k in 1:nn) {
## i <- comb[1, k]
## j <- comb[2, k]
## dif[k] <- means[i, 2] - means[j, 2]
## sdtdif <- sqrt(MSerror * (1 / means[i, 4] + 1 / means[j, 4]))
## pval[k] <- round(1 - stats::pf(abs(dif[k])^2 / ((ntr - 1) * sdtdif^2), ntr - 1, DFerror), 4)
## LCL[k] <- dif[k] - Tprob * sdtdif
## UCL[k] <- dif[k] + Tprob * sdtdif
## }
## pmat <- matrix(1, ncol = ntr, nrow = ntr)
## k <- 0
## for (i in 1:(ntr - 1)) {
## for (j in (i + 1):ntr) {
## k <- k + 1
## pmat[i, j] <- pval[k]
## pmat[j, i] <- pval[k]
## }
## }
## groups <- orderPvalue(means, alpha, pmat)
## names(groups)[1] <- name.y
## parameters <- data.frame(test = "Scheffe", name.t = name.t, ntr = ntr, alpha = alpha)
## rownames(parameters) <- " "
## rownames(statistics) <- " "
## rownames(means) <- means[, 1]
## means <- means[, -1]
## output <- list(
## statistics = statistics,
## parameters = parameters,
## means = means,
## comparison = NULL,
## groups = groups
## )
## class(output) <- "group"
## return(output)
## }
## <bytecode: 0x000001a81f73fb60>
## <environment: namespace:eCerto>
The test is originally based on:
“Steel, R.; Torri, J.; Dickey, D. (1997) Principles and Procedures of
Statistics: A Biometrical Approach. pp189”
Please prepare all data in a single Excel file on the first table (other tables will be neglected). Please stick to the column order and naming scheme as given in the example below.
A | B | C | D | E | |
|---|---|---|---|---|---|
1 | analyte | H_type | Flasche | value | unit |
2 | Fe | radial | 3 | 0.2897693 | mg/kg |
3 | Fe | radial | 36 | 0.2967753 | mg/kg |
4 | Fe | radial | 62 | 0.3075952 | mg/kg |
5 | Fe | radial | 78 | 0.3006643 | mg/kg |
6 | Fe | radial | 109 | 0.2981130 | mg/kg |
7 | Fe | radial | 144 | 0.3018592 | mg/kg |
8 | Fe | radial | 162 | 0.3051646 | mg/kg |
9 | Fe | axial | 200 | 0.2934924 | mg/kg |
10 | Fe | axial | 225 | 0.2369928 | mg/kg |
11 | Fe | axial | 239 | 0.2990771 | mg/kg |
12 | Fe | axial | 256 | 0.2916479 | mg/kg |
13 | Fe | axial | 295 | 0.2981732 | mg/kg |
... | ... | ... | ... | ... | ... |
Note! You may omit column
H_type (and also unit) in your Excel input
file if not needed.
The analyte column has to contain values that match the
corresponding data from the certification module. H_type
can be used to define different homogeneity traits for each analyte
which can yield independent uncertainty contributions.
Flasche encodes the different samples where repeated
measurements have been performed on. Each item in Flasche
should occur several times per analyte as these are your replicates to
be considered in the statistics. value has to contain
numeric values only to allow calculations. unit is neither
checked nor converted but used for plot annotation only.
Note! value data have to be
determined similarly (same unit) to the data from the
certification trial obviously to yield a meaningful uncertainty
value.
The uncertainty contribution of the Homogeneity measurements
u_bb (uncertainty between bottles) is calculated for each
analyte based on variance obtained by an ANOVA and is transferred to a
user specified column in the material table of the certification module
(Tab.C3).
Note! Values for u_bb can be
transferred to Tab.C3 in case that matching analyte
names are present (analyte names are depicted in red if not found).
Statistical differences between groups are nicely visualized using boxplots. While the ANOVA allows to calculate a probability testing the hypothesis that the mean values of different groups are similar or not, the boxplot visualizes the distribution of values within each group.
The box comprises 50% of the measured values of a group (from 25% to 75% quartile) and highlights the median (50% quartile). Overlapping boxes indicate that a t-test would not yield a significant P-value.
Within Fig.H1 dashed black and grey lines indicate \(\mu\) and \(s\) of the distribution of specimen means from Tab.H2.
Especially when several analytes are tested in a material using a small number of replicates per specimen, ANOVA might result in P-values below the alpha-level. Observing such a P-value does not automatically render the material non homogeneous. Due to multiple testing such observations might be False Positive results. However, they require a more careful inspection of the data to identify a potential systematic bias. To this end, eCerto offers several options:
We first conduct an analysis of variance (ANOVA) on a one factor
linear model for \(N\) bottles (or
containers) with \(n\) replicate
measurements each. The ANOVA is preformed for each analyte
and H_type (if specified during upload) independently. The
P-value of each ANOVA is provided in
Tab.H1 together with the variance within bottles \(s_w\) (M_within) and the
variance between bottles \(s_a\)
(M_between).
analyte | mean | n | N | Mbetween | Mwithin | P | sbb | sbb,min |
|---|---|---|---|---|---|---|---|---|
X | 0.0048 | 6 | 3 | 8.4E-06 | 2.7E-06 | 0.0748 | 0.2009 | 0.0838 |
Y | 532 | 6 | 3 | 436.1058 | 342.6525 | 0.3086 | 0.0074 | 0.0086 |
Z | 1.24 | 3 | 6 | 0.0020 | 0.0003 | 0.0050 | 0.0191 | 0.0054 |
A significant ANOVA P-value indicates non homogeneous specimen and is highlighted in red color in Tab.H1. P-values are adjusted for multiple testing in case of several analytes being under investigation per specimen using bonferroni correction. Adjustment can be switched off in the options panel next to Tab.H1.
Note! To account for the case of different number of replicates over all \(N\) bottles, \(n\) is calculated according to ISO GUIDE 35 as:
\[n=\frac{1}{N-1} \times \left[\sum_{i=1}^N{n_i}-\frac{\sum_{i=1}^N{n_i^2}}{\sum_{i=1}^N{n_i}}\right]\]
where \(n_{i}\) is the vector of replicates per group. Together with the overall mean vlaue \(\mu\) (mean of all \(N\) bottle means), we now can compute two relative uncertainties between bottles:
\[s_{bb}=\frac{\sqrt{\frac{s_a-s_w}{n}}}{\mu}\]
and
\[s_{bb, min}=\frac{ \sqrt{ \frac{s_w}{n} } \times \sqrt[4]{ \frac{2}{N \times (n-1)} }}{\mu}\]
Note! When \(s_{a} < s{_w}\) we set \(s_{bb}=0\).
The larger of both values, \(s_{bb}\) and \(s_{bb,min}\) (rendered in bold font), is selected as uncertainty contribution when the user decides to transfer an uncertainty value to the material table.
A transfer is only possible for analytes which have been found in the table of certified values (Tab.C3 in the certification module). Analytes not present there will be rendered in red.
Figures and tables can currently be exported in HTML or DOCX format.
Note! Report layout and format are currently under debate and might change in the future depending on user demand.
Stability data can be uploaded from an Excel file containing a single
table including columns analyte, Date,
Value and (optionally) unit. An additional
column Temp can be included. If present, eCerto
will try to perform shelf life calculations based on the Arrhenius
model.
eCerto will internally use the format “yyyy-mm-dd” for date values. It will try hard to convert other formats like “dd.mm.yyyy” from Excel correctly. Specifying a date instead of a relative time information is required to calculate shelf time and allows to continue using this data for long term stability monitoring.
A | B | C | D | E | |
|---|---|---|---|---|---|
1 | analyte | Date | Value | Temp | unit |
2 | a1 | 2022-01-01 | 2.2167549 | -20 | mg/kg |
3 | a1 | 2022-01-01 | 1.4575074 | -20 | mg/kg |
4 | a1 | 2022-01-01 | 2.8911446 | -20 | mg/kg |
5 | a1 | 2022-01-15 | 2.5959806 | 4 | mg/kg |
6 | a1 | 2022-01-15 | 3.6356180 | 4 | mg/kg |
7 | a1 | 2022-01-15 | 2.6892754 | 4 | mg/kg |
8 | a1 | 2022-01-15 | 0.7187534 | 23 | mg/kg |
9 | a1 | 2022-01-15 | 1.7868555 | 23 | mg/kg |
10 | a1 | 2022-01-15 | 3.8965399 | 23 | mg/kg |
11 | a1 | 2022-01-15 | 3.7768632 | 60 | mg/kg |
12 | a1 | 2022-01-15 | 2.5666045 | 60 | mg/kg |
13 | a1 | 2022-01-15 | 2.0157195 | 60 | mg/kg |
... | ... | ... | ... | ... | ... |
The Temp column obviously should contain temperature
levels in °C at which samples were stored before measurement. The lowest
temperature level will be used as a reference point \(T_\mathit{ctrl}\). This is also reflected
in the specified Date values, where \(T_\mathit{ctrl}\) will be treated as a
reference time point. All other temperature levels should have
later dates specified. For every measurement, the difference
between its date and the reference time point will be computed to
represent the storage time at this temperature.
Using dates instead of specifying storage time directly allows to compute stability and potential shelf life in both, relative (month) and absolute (date) values.
Upload can be also achieved from a previously created backup file.
The uncertainty contribution of the stability measurements
u_stab is calculated for each analyte based on a linear
model of Value on Date, or, more precisely, on
the monthly difference mon_diff calculated based on the
imported Date values.
The data and linear model is visualized in Fig.S1. Here, in addition to the monthly difference plotted on the bottom axis, start and end date of the data points are depicted at the top of the plot. The red line indicates the certified value \(\mu_c\) and the two green dashed lines provide either the standard deviation \(2s\) of the data or \(U_{abs}\) from the table of certified values, based on availability and user choice.
Fig.S1 Linear model plot visualizing stability data
Note! If no table of certified values is present or the analyte is yet unconfirmed, than red and green lines represent mean and standard deviation of the currently depicted stability data.
The dashed blue line indicates the linear model. It’s parameter \(b_1\) is reported in
Tab.S1 and used to calculate u_stab via
its Std. Error \(s(b_1)\) multiplied by
the shelf life \(t_{cert}\).
Alternatively, an adjusted version of the plot can be drawn. Adjusted means that the measured values are corrected by the differences between their mean and the value of \(\mu_c\). Let us assume that certified values are present in Tab.C3 and provided to the Figure drawing function. In this case \(\mu_c\) and \(U_{abs}\) are depicted together with \(U_{abs}/3\).
Fig.S1_adj Linear model plot visualizing stability data
Labels for constant values are depicted on the left side of the figure. On the right side, \(u_{LTS}\) is annotating the values calculated by \(t_{cert}*SE(b_1)\). Similarly, \(u_{CRM}\) is annotating the potential values of \(U_{abs}\) given that a specific \(u_{LTS}\), depending on the selection of \(t_{cert}\), is incorporated in tab.C3, thereby expanding the uncertainty. Because the value of \(u_{LTS}\) is incorporated in its quadratic form, \(u_{CRM}\) is a curve.
In contrast to the standard version of the stability plot, the confidence interval of the linear model slope \(CI_{95}(b_1)\) is shown.
The parameters of all linear models are collected in
Tab.S1 and the potential uncertainty contribution of
the material stability is obtained from formula \(u_{stab}={|t_{cert} \times s(b_1)| \over
\mu_s}\) where \(t_{cert}\) is
the expected shelf life of the CRM (in month) and \(s(b_1)\) is the standard error
SE of the slope of the linear model. \(\mu_s\) is calculated as the mean of all
values of an analyte depicted in Fig.S1, i.e. all
values included in the linear model calculation.
The expected shelf life can be set by the user and should incorporate the time until the first certification monitoring and the certified shelf life of the material. This estimation of stability uncertainty is based on section 8.7.3 of ISO GUIDE 35:2017 and valid in the absence of a significant trend.
To determine if the slope \(b_1\) is significantly different from \(b_1=0\) we perform a t-test by calculating the t-statistic \(t_m = |b_1| / s(b_1)\) and compare the result with the two-tailed critical value of Student’s \(t\) for \(n - 2\) degrees of freedom to obtain the P-values in column Pb1.
analyte | mondiff | b1 | s(b1) | tcert | µs | ustab | Pb1 | Ustab |
|---|---|---|---|---|---|---|---|---|
Mn | 88.3 | -0.0007 | 0.0037 | 60 | 97.4267 | 0.0023 | 0.8553 | 0.2205 |
Si | 88.3 | -2.0E-05 | 4.7E-06 | 60 | 0.2337 | 0.0012 | 0.0001 | 0.0003 |
Note! Selecting a table row in Tab.S1 will display the detailed analysis for the respective analyte.
Values from column ustab can be transferred to a user defined column of the material table Tab.C3 in the certification module for matching analyte names. Analytes of Tab.S1 which can not be matched to Tab.C3 are depicted in red.
Also Pb1 values lower than 0.05 are highlighted in red to indicate a slope significantly different from 0.
An optional column tmax can be displayed in Tab.S1 which will show the prospective maximum shelf life for each analyte (before ustab is transferred to Tab.C3). This value is calculated as the intersect of the linear line of ustab and the quadratic line representing uCRM/3, both of which are depicted in the adjusted version of Fig.S1. Once ustab is included in Tab.C3 tmax will not be relevant anymore because it would be calculated under the assumtion that the current ustab is additionally transferred to Tab.C3 (which would be redundant).
The Arrhenius approach is one way to estimate the stability of a reference material from the perspective of storage time or shelf life. As implemented in eCerto, the estimation is based on time series data of analytes at different temperature levels \(T_i\).
\(T_{min}\) is used as a reference point. For each \(T_i\) a linear model is calculated, yielding potentially a slope \(k_{\mathit{eff}}(T)\) indicative of analyte degradation. Combining all \(k_{\mathit{eff}}\) allows to estimate the dependency of analyte stability on temperature and, consequently, the expected storage time at a given \(T\).
The calculations are performed according to the recommendations for accelerated stability studies in ISO GUIDE 35:2017.
The analyte values measured at \(T_{min}\) are considered as stable and their mean is used as reference time point \(t=0\) for each temperature level \(T_i\). When measured values are depicted relative to this mean, eCerto calculates and annotates the recovery and RSD for each \(T_i\).
When the above ratios are log-transformed and the x-axis (time) is set to month, eCerto calculates the temperature-dependent reaction rates \(k_{\mathit{eff}}(T)\) as the slope for each linear model of \(T_i\).
Fig.S2 Calculation of degradation constants keff for tested temperature levels
Temperature levels in Fig.S2 are color coded with data points at t=0 in dark blue (indicative of T=-20°C) and tested levels of 4, 23 and 60°C in light blue, yellow and red, respectively. Grey horizontal lines indicate mean and standard deviation of the replicates at t=0 while colored lines indicate these values for each time point per \(T_i\). Note that the calculated slope of the linear model keff is depicted in red, indicating no degradation at the tested \(T_i\).
Besides Recovery and RSD for each
temperature level \(T_i\), the slope
k_eff and the log-transformation of it’s negative value
log(-k_eff) are provided in Tab.S2.
T [°C] | Rec | RSD | 1/K | keff | log(-keff) | log(k)calc | CIupper | CIlower | tmax |
|---|---|---|---|---|---|---|---|---|---|
4 | 254.2% | 27.1% | 0.003608 | -0.014340 | -4.244679 | -3.845631 | -3.154851 | -4.536410 | 45 |
23 | 218.6% | 46.5% | 0.003377 | -0.037268 | -3.289630 | -3.935000 | -3.466050 | -4.403949 | 61 |
60 | 241.5% | 35.9% | 0.003002 | -0.013219 | -4.326102 | -4.079780 | -3.321004 | -4.838557 | 53 |
In the case that at least 3 finite values for \(log(-k_{\mathit{eff}})\) exist, a linear
model over 1/K is calculated (depicted in
Fig.S3). Based on slope \(m\) and intercept \(n\) of this model values \(K_i\) (provided in
log(k)_calc) are established using \(K_i = m \times x_i + n\).
To estimate the confidence interval of the model
(CI_upper and CI_lower) we need to estimate
some intermediate values which are shown below Tab.S2.
First, eCerto calculates \(a=\sum{x_i}\), \(b=\sum{x_i^2}\) and \(n=length(x_i)\) where \(x_i\) are the inverse temperature values,
\(1/K\), as well as the standard error
\(err\) of the model:
\[err=\sqrt{\frac{1}{n-2} \times \sum{(y_i-\overline{y})^2} - \frac{\sum{(x_i-\overline{x}) \times (y_i-\overline{y})}^2}{\sum{(x_i-\overline{x})^2}}}\]
Next, these four calculated values \(a\), \(b\), \(n\) and \(err\) allow to compute the dependent variables:
\[u(i) = \sqrt{\frac{err^2 \times b}{(b \times n-a^2)}}\]
\[u(s) = \sqrt{\frac{err^2 \times n}{(b \times n-a^2)}}\]
\[cov = -1 \times \frac{err^2 \times a}{(b \times n-a^2)}\]
which, finally, can be used to estimate the confidence interval \(\mathit{CI}\) as:
\[\mathit{CI}_{(upper,~lower)} = K_i \pm \sqrt{ u(i)^2 + u(s)^2 \times x_i^2 + 2x_i \times cov }\]
When a certified value \(\mu_c\) and
corresponding uncertainty \(U_{abs}\)
(cert_val and U_abs) are available for an
analyte in Tab.C3 of the certification module of
eCerto, these can be used together with \(\mathit{CI}_{upper}\) to calculate the
storage time \(S_{Month}\) for each
evaluated temperature level using:
\[S_{\mathit{Month}}(T) = \frac{ \log( \frac{\mu_c - U_{abs}}{\mu_c})}{e^{\mathit{CI}_{upper}(T)} }\]
Note! Extrapolation beyond the range of storage conditions tested (for example, predicting degradation rates at −20°C from an experiment involving only temperatures above 0°C) can be unreliable and is not recommended.
The model parameters calculated in Tab.S2 are visualized in Fig.S3 plotting the log transformed negative \(k_{\mathit{eff}}(T)\) over the inverse temperature [1/K].
Fig.S3 Arrhenius model plot
The axis at the top of Fig.S3 indicates the corresponding temperature level for each data point in °C. The dashed red lines indicate the confidence interval As given in Tab.S2. Data points for Ti where keff>0 are omitted in the plot, as the log transformation is not defined for non-negative values.
The table of certified values (Tab.C3) combines all data collected within a certification trial to provide for each measured entity within the certified material the certified mean \(\mu_c\) and the certified uncertainty \(U_{abs}\).
analyte | mean | µc | sd | n | uchar | uhom | ucom | k | U | Uabs | unit |
|---|---|---|---|---|---|---|---|---|---|---|---|
X | 0.00478 | 0.004779 | 0.00026 | 4 | 0.0270 | 0.2009 | 0.2027 | 2 | 0.4054 | 0.001938 | mg/L |
Z | 1.26 | 1.26 | 0.02 | 29 | 0.0029 | 0.0191 | 0.0193 | 2 | 0.0387 | 0.05 | U |
Note! Only for analytes which have been
visually inspected by the user certified values will be transfered to
this table to ensure that inspection took place. The reported
mean is similar to the value obtained in
Fig.C1 but will be different to Tab.C2
when Labs are filtered for an analyte.
Several columns of the material table can be edited by the user by clicking in an individual cell and entering a new value.
Table column descriptions:
mean and sd give the arithmetric mean
\(\mu\) and standard deviation \(s\) for n analytical values of
this analyte similar to Fig.C1
n is dependent on pooling and gives the
number of values used for calculting \(\mu\) and \(s\). To this end, n is either
similar to the number of finite measurement values (pooling
allowed) or similar to the number of labs included in the analysis
(poolingnot allowed).
Example: We have an arbitrary analyte measured in three
laboratories with five replicates each. We can calculate \(\mu\) from all three laboratory averages
(poolingnot allowed, n=3). If a laboratory is
filtered, it will be grayed-out in the plot and not considered for \(\mu\) (n=2). If the user
decides to allow pooling than n will reflect
the number of finite measurement values from all labs for this analyte
(n = 2 x 5 = 10).
F columns can be added/edited and may contain
correction factors \(f_i\) to adjust
\(\mu\) and obtain the certified mean
by \(\mu_c = \mu \times \prod
f_i\)
u columns can be added and may contain relative
uncertainty contributions (e.g. from homogeneity or stability
modules)
Note! u columns containing
different uncertainty contributions should always be provided relative
to the mean to allow an easy combination of the individual terms. Only
U_abs is expressed as an absolute value.
u_char describes the characteristic
uncertainty, calculated as \(u_{char}=\frac{s}{\sqrt{n} \times
mean}\)
u_com is the combined uncertainty from all
u columns, where all relative uncertainty components \(u_i\) are combined using formula \(u_{com}=\sqrt{\sum{u_i^2}}\)
k is an additional expansion factor for the
uncertainty \(U=u_{com} \times
k\)
\(U_{abs}\) specifies the absolute uncertainty and is calculated by \(U_{abs}=U \times \mu_c\)
Note! Numeric values of \(\mu_c\) and \(U_{abs}\) are rounded to the number of
digits specified by the user at the analyte selection panel
(Precision µc). A precision according to DIN 1333
based on \(U_{abs}\) is suggested.
However, all relative u columns are depicted with fixed 4
digits precision.
Tab.C3 can be exported within a report using the download section on top of the page.
F and U columns in Tab.C3
can be added, removed or renamed using the drop down menu next to the
table. To add a new U column select option
<new U>, to rename an existing column, modify the
column in the text box. To delete a column, simply delete it’s column
name. All modifications take place only after the user confirms by
pushing the respective button within the drop down menu.
Note! eCerto will respect HTML
formatting, i.e. if you want to use subscript in your column
name you can use u<sub>hom</sub> as input to
create a column with displayed name uhom.
Default values are 1 and 0 for F and U
columns respectively, as these are neutral with respect to the result.
In F and U columns all values can be edited
manually by double clicking the respective cell, entering a new value
and clicking outside the cell to confirm the modification.
More conveniently, U columns can also be filled
automatically with data from the homogeneity and stability modules of
eCerto.
Note! Manual modifications will be overwritten by any automatic transfer into the same column.
The only other column which can be manually edited is k,
the expansion factor for u_com. All other columns can not
be modified by the user and will only show a grey background upon double
click. This is on purpose to ensure a robust workflow and comprehensible
statistical results. It requires a careful preparation of input data
files, e.g. providing reasonable and consistent analyte names and
units.
To check if the certified value of a CRM \(\mu_c\) remains stable, a post certification measurement can be performed and evaluated according to ISO GUIDE 35:2017 (8.10.3.2) by calculating a stability criteria \(\mathit{SK}\) using formula:
\[\mathit{SK} = {|\mu_c - \mu_m| \over \sqrt{u_c^2 + u_m^2}}\]
where \(\mu_m\) is the mean and \(u_m = \sigma / \sqrt{N}\) is the standard uncertainty of post certification measurements performed on a CRM specimen, and where \(u_c = u_{com} \times \mu_c\) is the absolute certified uncertainty without expansion.
If \(\mathit{SK} \le k\) is fulfilled, this indicates that the material is sufficiently stable.
Note! \(k\) is set based on the expansion factor associated with the analyte given in Tab.C3. It is recommended to keep \(k=2\) as this will ensure a 95% confidence for \(\mathit{SK}\).
eCerto can be used to monitor long term stability of a material. To this end, two approaches were implemented. A quick post certification check for stability can be preformed in the Certification module next to Tab.C3. There, calculation of \(\mathit{SK}\) allows to access if analyte values within a material can still be considered stable at measurement time of control samples.
However, to estimate long term stability prospectively, measurement data can be continuously obtained and stored using the LTS module of eCerto as described below.
Please prepare data in a single Excel file on separate tables for
each measured value (KW, Kennwert) as shown in the below example. Table
and File names are not evaluated. Instead, each table is expected to
contain the metadata in rows 1-2 and the measurement data from row 4 on
wards. Column names need to be exactly as in the example and should
match the desired format (e.g. Value and Date
columns should be of numeric and date format respectively).
A | B | C | D | E | F | G | H | I | J | K | |
|---|---|---|---|---|---|---|---|---|---|---|---|
1 | RM | KW | KW_Def | KW_Unit | CertVal | U | U_Def | Device | Method | Coef_of_Var | acc_Datasets |
2 | CRM X1 | ABET | Surface Area | m2/g | 5.41 | 0.24 | 1s | ASAP2020 | Gassorption | 0.0443 | 30 |
3 | |||||||||||
4 | Value | Date | File | Comment | |||||||
5 | 0.262 | 04.01.2011 | File_1.smp | ||||||||
6 | 0.133 | 05.01.2011 | File_2.smp | some text | |||||||
7 | 0.91 | 06.01.2011 | File_3.smp | ||||||||
... | ... | ... | ... | ... | |||||||
34 | 0.212 | 02.02.2011 | File_30.smp |
The File column can be used to reference the data source
for traceability of measurement values. The Comment column
can be used to provide additional information.
The meta data information can not be further edited in
eCerto. Hence, the user should carefully consider the provided
data. U_Def for example should specify which uncertainty
value was originally certified and is provided in U. This
can be one out of five potential options:
1s or 2s indicating the simple or double
varianceCI confidence interval1sx or 2sx indicating the relative simple
or double varianceOther values will not be recognized correctly. Most meta data values will be used for plot annotations and in the LTS report only and can be omitted. However, to comply with the rules for good scientific practice it is recommended to provide them.
The Tool calculates the expected life time of a reference material in several steps:
The calculation results are depicted in Fig.L1 and can be exported as a report in PDF format.
Note! The \(U\) defining the interval around \(\mu_c\), which we expect the property values to remain in within the RM life time, is taken from the data read upon initial Excel import. The user should be careful regarding the value specified here to avoid overestimating the life time. LTS monitoring, which is usually performed within the same lab, will cover mostly the uncertainty due to stability of a material property. The uncertainty defined in the original certificate will cover additional uncertainty contributions (i.e. from the collaborative trial). Hence, it might be adequate to use only a fraction of the certified \(U\) value to define the interval.
Note! The parameters of a linear model, i.e. \(b_1\), can only be determined with some uncertainty. While the current report layout calculates the life time based on \(b_1\) as described above, a more conservative estimate would be to use the confidence interval, \(CI_{95}(b_1)\), instead. Calculation based on \(CI_{95}(b_1)\) is shown in Fig.L1 by default.
After data upload, the user can add new data points for a selected
property by manually editing the 4 fields in the input area and clicking
on the button Add data.
Comments to a data point are optional. To prevent non-deliberate
modification of measurement data, only comments can be changed by the
user after data upload. Comment modification can be conviniently
performed by selecting a data point, either in Tab.L1
or in Fig.L1, entering a new text in the
comment input field and confirming the modification by
clicking the button Add comment.
The user can export a PDF report containing all imported, edited and calculated data and figures.
Note! The Validation module is an add-on to eCerto. It is not required to compute CRM statistics. It is ment to:
As it is currently work-in-progress, available options and output format might change in the future.
eCerto implements statistical procedures for analytical method validation according to DIN 32645:2008-11.
The method performance characteristics reported by eCerto comprise working range, linearity, limit of detection (LOD) and limit of quantification (LOQ) together with statements on trueness, precision and uncertainty.
The statistical tests implemented in eCerto according to DIN 32645:2008-11 comprise outlier tests (Grubbs), trend tests (Neumann), tests for homogeneity of variance (F-Test), …
The implemented formulas are provided or referenced in the respective help sections.
To compute the relevant performance characteristics of an analytical method, eCerto will evaluate replicate measurements of a dilution series of samples containing any number of target analytes and their internal standards.
For advice on concentration range, replicate number and calibration levels tested, we refer to DIN 32645:2008-11
Please prepare your data in an Excel file with the same format as shown below.
A | B | C | D | E | F | G | |
|---|---|---|---|---|---|---|---|
1 | Name | Type | Level | Analyte | Concentration | Area_Analyte | Area_IS |
2 | 20240522_K1_1 | Cal | 1 | PFBA | 0.106 | 7437.591 | 64545.49 |
3 | 20240522_K1_2 | Cal | 1 | PFBA | 0.106 | 7536.128 | 65770.33 |
4 | 20240522_K1_3 | Cal | 1 | PFBA | 0.106 | 7287.595 | 64905.09 |
5 | 20240522_K1_4 | Cal | 1 | PFBA | 0.106 | 7537.075 | 66523.44 |
6 | 20240522_K1_5 | Cal | 1 | PFBA | 0.106 | 7673.837 | 67254.20 |
7 | 20240522_K1_6 | Cal | 1 | PFBA | 0.106 | 7585.387 | 67337.18 |
8 | 20240522_K1_7 | Cal | 1 | PFBA | 0.106 | 7695.904 | 67039.86 |
9 | 20240522_K1_8 | Cal | 1 | PFBA | 0.106 | 7657.696 | 67613.31 |
10 | 20240522_K1_9 | Cal | 1 | PFBA | 0.106 | 7727.769 | 67345.65 |
11 | 20240522_K1_10 | Cal | 1 | PFBA | 0.106 | 7795.144 | 67584.19 |
12 | 20240522_K2_1 | Cal | 2 | PFBA | 0.295 | 15341.895 | 69263.91 |
13 | 20240522_K2_2 | Cal | 2 | PFBA | 0.295 | 15455.544 | 69221.12 |
14 | 20240522_K2_3 | Cal | 2 | PFBA | 0.295 | 15463.154 | 70331.48 |
15 | 20240522_K2_4 | Cal | 2 | PFBA | 0.295 | 15865.875 | 70521.55 |
16 | 20240522_K2_5 | Cal | 2 | PFBA | 0.295 | 15743.460 | 70612.11 |
17 | 20240522_K2_6 | Cal | 2 | PFBA | 0.295 | 15658.938 | 69889.95 |
18 | 20240522_K2_7 | Cal | 2 | PFBA | 0.295 | 15676.385 | 70471.94 |
19 | 20240522_K2_8 | Cal | 2 | PFBA | 0.295 | 15298.268 | 68734.10 |
20 | 20240522_K2_9 | Cal | 2 | PFBA | 0.295 | 15916.635 | 70440.43 |
21 | 20240522_K2_10 | Cal | 2 | PFBA | 0.295 | 15850.760 | 70829.99 |
22 | 20240522_K3_1 | Cal | 3 | PFBA | 0.952 | 43547.629 | 70864.98 |
23 | 20240522_K3_2 | Cal | 3 | PFBA | 0.952 | 43775.431 | 70776.10 |
24 | 20240522_K3_3 | Cal | 3 | PFBA | 0.952 | 43476.944 | 71057.64 |
... | ... | ... | ... | ... | ... | ... | ... |
The optional columns Name and Type are
recommended for later reference. They will be filled with dummy data if
not present. All measurement values used in calculations will be of Type
Cal, i.e. originating from a calibration sample with a
defined concentration for each analyte. The observed peak area values of
analytes and their internal standards (IS) are used to perform
calculations of method validation.
Alternatively you can provide data in a single Excel file exported by Agilent MassHunter Software.
The information in columns Name and Type
are kept for later reference only. The information on analyte names is
extracted from the red area. The information on calibration levels
(similar for all analytes) and according analyte concentrations within
each level (analyte specific) is used as the independent variable \(x\) in all figures and tables. The
information on peak area of each analyte and its respective internal
standard (IS) is used to calculate the dependent variables \(y=f(x)\) in all figures and tables.
Note! Empty cells in the columns
Level and Exp. Conc. will be filled with the
closest finite value above, i.e. it is assumed that all samples in rows
4 to 12 in the example are replicates of calibration level 1 (as defined
in row 3).
eCerto will try to determine the used format upon upload automatically.
You can store any data imported from Excel together with all specified parameters in an RData file. Such an RData file can be loaded similar to one of the Excel files described above. The advantage in using such an RData file is that user defined parameters (alpha, k, filters…) are stored together with the raw data.
The working range of an analytical method is tested using the relative analyte values \(x_r\) of the smallest and the largest calibration level, \(j_1\) and \(j_N\), respectively.
Relative analyte values are computed as \(x_r = \frac {x_{i,j}} {\overline{x}_j}\) with \(x_{i,j}\) being the peak area ratios of analyte and internal standard \(x_{i,j}=\frac{A_\text{Analyte}}{A_\text{IS}}\) for each replicate \(i\) and calibration level \(j\).
For each \(x_j\) in total \(i=1..n\) replicate values exist and are tested:
Statistical test results are indicated in Fig.V1 by colored symbols as \(ns=\) not significant (green color), \(*=\) significant at \(P\le0.05\) (orange color) and \(**=\) significant at \(P\le0.01\) (red color).
The two min/max calibration levels \(j_1\) and \(j_N\) are tested for homogeneity of variance using an F-Test. The user has the option to select other calibration levels as min or max, i.e. \(j_2\) or \(j_{N-1}\). In case of a significant F-Test (no variance homogeneity), this allows to limit the working range to acceptable values.
The linearity of an analytical method is tested using the mean normalized analyte values at different concentrations \(\overline{x}_j\).
Analyte values are computed for each replicate \(i\) at calibration level \(j\) as the peak area ratios of analyte and internal standard \(x_{i,j}=\frac{A_{Analyte}}{A_{IS}}\). Here, \(\overline{x}_j\) is the mean of the \(i=1..n\) replicates at level \(j\). The total number of calibration levels is denoted as \(N\).
For each analyte, a linear model \(y=b_0+b_1 \times x\) over all \(\overline{x}_j\) is computed and the following parameters are reported:
Additionally, the residuals \(e\) of the linear model are tested:
Note The F-Test is applied sequentially until no further outlier is detected.
For comparison the data is fitted using a quadratic model \(y=b_0+b_1 \times x+b_2 \times x^2\). The residuals from both models, the linear and the quadratic one, are compared using a Mandel-Test calculating \(P_{Mandel}\).
The trueness of an analytical method, which describes the consistency between an analytical result and a reference value, can be tested in different ways. Possible procedures are analysis of a reference material, comparison to a (different) reference method or analysis of samples of specified concentration(s).
For the latter, \(n \le 6\) independent samples should be prepared and analyzed at 3 different concentration levels \(j\) covering the working range. For each level, the recovery should be calculated by comparison with the reference value as \[R = \frac{\overline{x_j}}{x_{r,j}} \times 100\%\] where \(\overline{x_j}\) is the mean value of all replicates at level \(j\) and \(x_{r,j}\) is the according reference value. Recovery values \(80\% \le R \le 120\%\) are acceptable.
Currently, eCerto only allows to copy/paste a statement regarding the recovery calculations which will be stored together with the other data and incorporated in the report.
The precision of an analytical method, which describes …, can be obtained by ….
Currently, eCerto only allows to copy/paste a statement regarding the precision calculations which will be stored together with the other data and incorporated in the report.
The uncertainty of an analytical method, which describes …, can be obtained by ….
Currently, eCerto only allows to copy/paste a statement regarding the uncertainty calculations which will be stored together with the other data and incorporated in the report.
This is the collection of abrreviations and formulas used in the method validation module of eCerto. While the calculations follow generally the recommendations given in DIN 32645:2008-11, we hope that this redundancy may serve as a quick reference when using eCerto.
| Symbol | Description |
|---|---|
| \(N_j\) | total number of calibration levels with \(j\) denoting the j-th level |
| \(n_i\) | (minimal) number of replicates within a calibration level with \(i\) denoting the i-th replicate |
| \(x_{i,j}\) | denoting the normalized analyte value, the ratio of analyte and internal standard (IS) peak areas in replicate \(i\) of level \(j\) calculated as \(x_{i,j}=\frac{A_\text {Analyte}}{A_\text {IS}}\) |
| \(\overline{x}_j\) | mean of normalized analyte values at concentration \(j\) |
| \(x_r\) | denoting the relative analyte level \(x_r = \frac {x_{i,j}} {\overline{x}_j}\) |
| \(b_0, b_1, (b_2)\) | denoting the coefficients (intercept, slope, …) of a linear (quadratic) model fitting the data |
| \(e\) | denoting the residuals (error) of a model |
| \(k\) | denoting the result uncertainty specified by the user |
| \(t_{f,\alpha}\) | denoting the \(t\) distribution with \(f\) degrees of freedom and probability \(\alpha\) |
| \(s_{x,y}\) | denoting the standard error of estimate of a linear model of \(N\) levels with residuals \(e\) calculated as \(s_{x,y}=\sqrt{\frac{\sum e^2}{N-2}}\) |
| \(\text {LOD}\) | limit of detection of a linear model of \(N\) levels with \(n\) replicates having slope \(b_1\) and residuals \(e\) calculated as \(\text {LOD} = k \times \frac {s_{x,y}} {b_1} \times t_{f,\alpha} \times \sqrt {{\frac {1} {n}} + {\frac {1} {N}} + \frac {\overline{x}^2} {\sum (x-\overline{x})^2}}\) where \(f = N-2\) and \(\alpha\) is specified by the user |
| … | (to be completed) |
The user can export a report, in HTML or docx format, containing all imported, edited and calculated data and figures.
For later reference, all data and parameters can be stored (and reimported) in an RData file.
Please prepare your data in an Excel file with the same format as shown below.
A | B | C | D | E | F | G | H | |
|---|---|---|---|---|---|---|---|---|
1 | Property | Unit | Lab | Level | Replicate | Value | ID | Filter |
2 | measurand name | measurand unit | Lab01 | Lev01 | 1 | 10.0010 | 1 | |
3 | measurand name | measurand unit | Lab01 | Lev01 | 2 | 10.4160 | 2 | |
4 | measurand name | measurand unit | Lab01 | Lev01 | 3 | 10.0200 | 3 | |
5 | measurand name | measurand unit | Lab01 | Lev01 | 4 | 10.1840 | 4 | |
6 | measurand name | measurand unit | Lab01 | Lev01 | 5 | 9.9990 | 5 | |
7 | measurand name | measurand unit | Lab02 | Lev01 | 1 | 9.3420 | 6 | |
8 | measurand name | measurand unit | Lab02 | Lev01 | 2 | 8.9160 | 7 | |
9 | measurand name | measurand unit | Lab02 | Lev01 | 3 | 9.5100 | 8 | |
10 | measurand name | measurand unit | Lab02 | Lev01 | 4 | 9.5900 | 9 | |
11 | measurand name | measurand unit | Lab03 | Lev01 | 1 | 10.2082 | 10 | |
12 | measurand name | measurand unit | Lab03 | Lev01 | 2 | 9.9405 | 11 | |
13 | measurand name | measurand unit | Lab03 | Lev01 | 3 | 9.8556 | 12 | |
14 | measurand name | measurand unit | Lab04 | Lev01 | 1 | 9.3010 | 13 | |
15 | measurand name | measurand unit | Lab04 | Lev01 | 2 | 9.9920 | 14 | |
16 | measurand name | measurand unit | Lab04 | Lev01 | 3 | 9.3260 | 15 | removed ID 15 |
17 | measurand name | measurand unit | Lab04 | Lev01 | 4 | 9.9540 | 16 | |
... | ... | ... | ... | ... | ... | ... | ... | ... |
The optional columns are depicted in grey. Column order is not relevant but column names are. ‘Lab’ and ‘Level’ can be specified as number or text, ‘Replicate’ and ‘Value’ have to be numbers.
Functions and output have been tested using the example data B1, B2 and B3 from DIN 5725-2 and confirmed to be in accordance with the presented results.